Particulars |
Spot Welders |
Model |
|
Unit |
HS-20 |
HS-30 |
HS-50 |
HS-75 |
KVA Rating@50% Duty Cycle |
|
KVA |
20 |
30 |
50 |
75 |
Nominal Throat Clearance |
|
MM |
250 |
250 |
250 |
250 |
Throat Depth |
|
CM |
50 |
50 |
50-60 |
50-75 |
Max. Available Short Circuit Current |
|
K Amps |
12 |
18 |
23-18 |
26-20 |
Max. electrode Force @ 6 Kg/Cm2 |
|
|
450 |
450 |
480 |
480 |
Upper Electrode Stroke Max |
|
MM |
50 |
50 |
50 |
50 |
Primary Supply Voltage |
|
Volts |
415 |
415 |
415 |
415 |
|
(2 Lines of 3 Phase Supply) |
Insulation Class |
|
A |
A |
A |
A |
A |
Machine Dimension |
L |
MM |
1100 |
1100 |
1350 |
1350 |
|
W |
MM |
500 |
500 |
600 |
650 |
|
H |
MM |
1640 |
1640 |
1750 |
1750 |
Approx Weight With Arm |
|
KGS |
220 |
250 |
295 |
360 |
Customer to Provide the Following Services |
Customer to Provide the Following Services |
External Water supply at max. Temp. 300 C |
|
Lit./Min |
7 |
7 |
10 |
10 |
Size of mains supply Copper Cable |
|
MM2 |
16 |
25 |
35 |
50 |
Main Supply switch Fuse Rating 500 Volts. |
|
Amps |
35 |
75 |
100 |
150 |
Delayed Action Fuse Rating Amps. |
|
Amps |
30 |
60 |
90 |
140 |